● Mold Introduction
Resin
PEEK K6000
Surface Requirement
VDI19 EDM texture on cosmetic surface, uniform texture. No gas marks, flow marks, trapped air, drag marks or color variation.
Technical Specification
Critical dimension tolerance ±0.015 mm. Max mismatch 0.03 mm. Zero flash on functional mating areas; Max flash 0.05 mm on non-functional areas. Heater rods are installed on both cavity and core sides of the mold, constant mold temperature 200℃ during injection molding. Cavity insert / mold base adopts imported mold steel with high strength and high heat resistance.
Orthopedic Handheld Medical Device End Cap
● Mold IntroductionCavity1×2ResinABS CYCOLAC MG47F BK4500Surface RequirementVDI32 EDM texture on cosmetic surface, uniform texture. No gas marks, flow marks, trapped air, drag marks or color variati...
● Mold Introduction
Cavity
1×2
Resin
ABS CYCOLAC MG47F BK4500
Surface Requirement
VDI32 EDM texture on cosmetic surface, uniform texture. No gas marks, flow marks, trapped air, drag marks or color variation.
Technical Specification
Critical dimension tolerance ±0.015 mm. Max mismatch 0.03 mm. Zero flash on functional mating areas; Max flash 0.1 mm on non-functional areas. The Ø0.35 mm piercing small holes adopt imported mold steel with high hardness and high toughness.
Precision Air Duct Cover for Orthopedic Handheld Medical Device
● Mold IntroductionCavity1×2ResinABS CYCOLAC MG47FSurface RequirementMT11020 + A2 mirror finish on cosmetic surface, uniform texture. No gas marks, flow marks, trapped air, drag marks or color varia...
● Mold Introduction
Cavity
1×2
Resin
ABS CYCOLAC MG47F
Surface Requirement
MT11020 + A2 mirror finish on cosmetic surface, uniform texture. No gas marks, flow marks, trapped air, drag marks or color variation.
Technical Specification
Critical dimension tolerance ±0.015 mm. Max mismatch 0.03 mm. Zero flash on functional mating areas; Max flash 0.1 mm on non-functional areas.
Orthopedic Handheld Medical Device Handle Housing
● Mold IntroductionCavity1×1ResinPA6+30%GFSurface RequirementMT11010 texture on cosmetic surface, uniform texture. No fiber blooming, gas marks, flow marks, trapped air, drag marks or color variatio...
● Mold Introduction
Cavity
1×1
Resin
PA6+30%GF
Surface Requirement
MT11010 texture on cosmetic surface, uniform texture. No fiber blooming, gas marks, flow marks, trapped air, drag marks or color variation.
Technical Specification
Critical dimension tolerance ±0.015 mm. Max mismatch 0.03 mm. Zero flash on functional mating areas; Max flash 0.1 mm on non-functional areas. High-precision positioning blocks are adopted in the mold to prevent mismatch during injection molding.